2d ionization chamber array matrixxone (IBA Dosimetry)
Structured Review
2d Ionization Chamber Array Matrixxone, supplied by IBA Dosimetry, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/ionization+chamber+2d+array/the+matrixx+evolution+2d+ionization+chamber+array/pmc12138570-65-15-20
Average 90 stars, based on 1 article reviews
Images
Related Articles
other:Article Title: Single pencil beam benchmark of a module for Monte Carlo simulation of proton transport in the PENELOPE code. Article Snippet: Article Title: Second Cancer Risk after simultaneous integrated boost radiation therapy of right sided breast cancer with and without flattening filter. Article Snippet: Background The aim of this study was to investigate if the flattening filter free mode (FFF) of a linear accelerator reduces the excess absolute risk (EAR) for second cancer as compared to the flat beam mode (FF) in simultaneous integrated boost (SIB) radiation therapy of right-sided breast cancer.. Patients and methods Six plans were generated treating the whole breast to 50.4 Gy and a SIB volume to 63 Gy on CT data of 10 patients: intensity-modulated radiation therapy (IMRT), volumetric modulated arc therapy (VMAT), and a tangential arc VMAT (tVMAT), each with flattening filter and without.. The EAR was calculated for the contralateral breast and the lungs from dose–volume histograms (DVH) based on the linear-exponential, the plateau, and the full mechanistic dose–response model. Article Title: Simultaneous integrated boost therapy of carcinoma of the hypopharynx/larynx with and without flattening filter - a treatment planning and dosimetry study Article Snippet: All 40 plans were dosimetrically verified using the MatriXX EvolutionTM 2D–ionization-chamber-array (IBA Dosimetry, Schwarzenbruck, Germany) set up in between slabs of a RW3 phantom (PTW, Freiburg, Germany). Article Title: Dose verification of IMRT by use of a COMPASS transmission detector. Article Snippet: Our purpose in this study was to evaluate the fundamental accuracy of reconstructed dose distributions from the COMPASS system using specific MLC test patterns and complicated IMRT neck plans.. The COMPASSreconstructed dose distributions were compared with those measured with EPID, MapCHECK, and EDR2 film and as well as Monte Carlo-calculated dose profiles with use of square-wave chart patterns of 20-, 10-, and 5-mm gaps and step and pyramid patterns.. Additionally, the COMPASS dose distributions for clinical IMRT neck plans were tested. Article Title: Second cancer risk after radiation therapy of ependymoma using the flattening filter free irradiation mode of a linear accelerator Article Snippet: Dose verification of all IMRT and VMAT plans was performed with the MatriXX EvolutionTM 2D ionization chamber array (IBA Dosimetry, Schwarzenbruck, Germany) positioned between a 10 cm (bottom) and a 9.7 cm (top) stack of RVW slabs (PTW, Freiburg, Germany). Article Title: First Clinical Implementation of Step-and-Shoot Proton Arc Therapy for Head and Neck Cancer Treatment Article Snippet: QA procedures included measurement-based verification using a phantom setup to validate the dose distribution via Article Title: Characterization and use of a 2D-array of ion chambers for brachytherapy dosimetric quality assurance. Article Snippet: The two-dimensional (2D) ionization chamber array MatriXX Evolution is one of the 2D ionization chamber Received 08 April 2011 Accepted 13 September 2011 arrays developed by IBA Dosimetry (IBA Dosimetry, Germany) for megavoltage real-time absolute 2D dosimetry and verification of intensity-modulated radiation therapy (IMRT).. The purpose of this study was to (1) evaluate the performance of ion chamber array for submegavoltage range brachytherapy beam dose verification and quality assurance (QA) and (2) use the end-to-end dosimetric evaluation that mimics a patient treatment procedure and confirm the primary source strength calibration agrees in both the treatment planning system (TPS) and treatment delivery console computers.. The dose linearity and energy dependence of the 2D ion chamber array was studied using kilovoltage X-ray beams (100, 180 and 300 kVp). Article Title: Proton minibeam (pMBRT) radiation therapy: experimental validation of Monte Carlo dose calculation in the RayStation TPS. Article Snippet: Background: Proton minibeam radiation therapy (pMBRT) is a spatially fractionated radiation therapy (SFRT) modality that uses a multi-slit collimator (MSC) to create submillimeter slit openings for spatial dose modulation.. The pMBRT dose profile is characterized by highly heterogeneous dose in the plane perpendicular to the beam and rapidly changing depth dose profiles.. Dose measurements are typically benchmarked against in-house Monte Carlo simulation tools. |